If you need to install an outdoor electrical outlet because you need to power a pond pump or other device think safety.
Underground power cable conduit.
But it can be difficult to fish cable through conduit unless the conduit is at least 3 4 inch in diameter.
Metal electrical boxes must be used with metal conduit.
Secure the cable to the overhead joists with cable staples.
Conduit cable fill chart this chart for conduit size for cable is based on the 2017 nec and uses common conduit types and wires.
Deep pvc conduit method we show is about the easiest and most practical for running a typical 15 amp line.
Find the type of conduit that you want to use in table 4.
Nec 300 5 underground wiring conduit movement protection where subject to movement direct buried cables or raceways shall be arranged to prevent damage to the enclosed conductors or connected equipment.
Prewired conduit or armored cable offers an all in one solution with the wires already running through it.
Running uf cable through metal or pvc conduit.
However keep in mind that no cable or conduit is protected from digging by construction equipment such as trench diggers or backhoes.
If necessary use a propane powered heat gun to bend the conduit to conform to the foundation.
Decide how much digging you re prepared to do which determines the type of wire you need to use.
Sizing the conductors.
Electrical cable depth options.
Underground cable for running electrical power to a remote location can be installed at different depths depending on the type of conduit and type of wire used.
Attach a plastic conduit outlet body to the end of the conduit.
Flexible metallic conduit bends and twists easily allowing turns at corners without the use of elbow joints.
Push a length of uf underground feed electrical cable into the conduit then feed the end of the cable through the hole in the house wall.
For a 6 in deep trench use galvanized rigid metal electrical conduit with individual conductors inside.
Attach a plastic conduit outlet body to the end of the conduit.
If you re using electrical metal tubing emt conduit you ll see that the closest size that you need is a 1 in conduit which gives you a 39 fill.
There are several different methods for safely running the underground wiring but the 12 in.
Nec 300 5 underground wiring conduits emerging from the ground conductors emerging from underground shall be installed in rigid metal conduit.
Push a length of uf underground feed electrical cable into the conduit then feed the end of the cable through the hole in the house wall.
Although not commonly done it is allowable to run uf cable but not nm cable through metal or pvc conduit in an underground application.
From inside the basement pull the cable all the way to the main electrical panel.